Laboratory Test Request

Sling Hoist Performance Testing - ISO 10535

Project Description

Need ISO 10535 testing of slings we manufacture. The test must follow the instruction outlined in Section 8.3 of ISO 10535 (Hoists for the transfer of persons).


Test Details:

The body support unit is designed to be laundered; it shall be cleaned and dried 10 times in accordnace with manufacturer's instruction (Normal wash at 80°C. Do not bleach. Tumble dry low. Do not iron. Do not dry clean. Use mild detergent) and then tested with a static load of 1.5x maximum load for 20 mins.

After the test, it shall be subjected to an extensive inspection during which attention shall be given to all parts. i.e. fabric, seams, stitching, loops, loop fixation, and Fabric at the positions in which rigid parts are received on the fabric. After the test, no part shall show any sign of damage or wear.  Please provide a quote for the above testing.

Project Information

Number:25-00444

Industry:Hospitals and Medical Centers

This request is open and accepting quotes! Register or Log In to unlock more information or respond to this request.