Project Description
Electrical communications laboratory needed for IEC 61537 Cl. 10.2-10.8 testing of cable tray and ladder systems with respect to the following:
1. SWL loading IEC 61537 Cl. 10.2-10.8 (and Annex D.1) (to residual deflection
measured by instruments with a resolution of 0.5mm or better and a precision
of 0.1 mm or better in all range of the equipment per cl. 5.9).
D.1 states Trays mesh, solid, perforated to use load distribution plates that are rectangular,
120 mm by 40mm with a tolerance of 1mm.
Project Information
Number:17-00399
Industry:Qualification