Laboratory Test Request

ASHRAE Testing of Refrigeration Oils

Project Description

MULITPLE TESTING
Third-Party Laboratory for ASHRAE Testing of refrigeration oils using sealed glass tube test per latest ASHRAE-97 test procedure (Sealed Glass Tube Method To Test The Chemical Stability Of Materials For Use Within Refrigerant Systems).
1. VG-32
2. VG-22
3. VG-10
The testing has to be carried out at 200*C for 14 days and observations after 14 days with HFO refrigerant. The test parameters are:
1. ASHRAE 97-2007/ latest ASHRAE method.
2. All test parameters should be evaluated after 14 days of exposure at 200*C.
3. Pre / Post analysis of oil for TAN, Moisture, ICP analysis .
4. Photographs of before and after exposure.
5. Percentage formation of other refrigerants after 14 days exposure at 200*C.
5. Sample preparation before testing: Please ensure that samples should have less than 35ppm moisture before charging refrigeration oil in a sealed glass tube, if during transportation/handling it is higher then remove extra moisture by vacuum/Fuller earth treatment and filtration or any other suitable
technique.
6. Separate test report for each refrigeration oil tested as per ASHRAE97.

Project Information

Number:24-01448

Industry:Refrigeration Oil

This request is closed and is no longer accepting quotes. Register or Log In to receive alerts when similar requests open in the future.
Industrial Oils,Refrigeration Oil,

Test Request: 24-02071

MULTIPLE SAMPLES Large Corporation needs a third-party laboratory for running sealed glass tube tests on refrigeration ... view


Test Request: 23-01952

MULTIPLE TESTING Refrigeration Company needs USA Contract Laboratory for analysis of two pipe thread lubricants and the... view


Test Request: 23-00842

MULTIPLE TESTING Analytical Laboratory needed for testing an oil product for ASTM D-5-5864 and OECD 301B biodegradabili... view