Laboratory Test Request

Insulating Oil Sample Testing

Project Description

MULTIPLE TESTING
Industrial Laboratory needed for Lubricants testing for an immersion insulating oil sample for the following tests with the given methods.

1- Oxidation Stability - IEC 61125
2- Maximum moisture content for dielectric breakdown ASTM D1533-20
3- Volume Resistivity ASTM D1169
4- Optical Refractive Index from 20 to 70C ASTM 1218
5- Dielectric Withstand Voltage 1 mm gap (ASTM D 1816)

Please confirm the price, how much sample qty is needed for each & lead time to get the reports.
Appreciate your quick response on the subject.

Project Information

Number:23-01300

Industry:Industrial Oils

This request is closed and is no longer accepting quotes. Register or Log In to receive alerts when similar requests open in the future.
Industrial Lubricants,Industrial Oils,Insulating Oils,Lubricants,Lubricating Oils,Industrial,Industrial Oils,Chemicals,